Terminations

Precision Low VSWR Termination

 

  • Operating Frequencies: 1.70 - 50.00 GHz

  • Waveguide is Standard Copper or Aluminum Alloy

  • Power Handling 2 to 37 Watts

  • VSWR 1.01:1 MAX (Fullband)

  • Finish: High Temperature Flat Black, RoHS Compliant*

  • Pressurized

Low Power Termination

 

  • Operating Frequencies: 1.70 - 50.00 GHz

  • Waveguide Standard Material Copper or Aluminum Alloy

  • Power Handling 5 or 25 Watts (Specify in part number)

  • VSWR 1.07:1 MAX

  • Fullband VSWR 1.15:1 MAX

  • Finish: High Temperature Flat Black, RoHS Compliant*

  • Pressurized

Medium Power Termination

 

  • Operating Frequencies: 1.70 - 50.00 GHz

  • Waveguide is Standard Copper or Aluminum Allow

  • Power Handling 20 to 1200 Watts

  • Fullband VSWR 1.10:1 MAX

  • Finish High Temperature Flat Black, RoHS Compliant*

  • Pressurized

High Power Termination

 

  • Operating Frequencies: 1.70 - 50.00 GHz

  • Waveguide is Standard Copper or Aluminum Alloy

  • Power Handling 250 to 5000 Watts

  • Fullband VSWR 1.10:1 MAX

  • Finish: High Temperature Flat Black, RoHS Compliant*

  • Pressurized